SURGICAL ROBOTS IN NEUROSURGERY

M. Kumari

A surgical robot is a robot that allows surgeons greater access to areas under operation using more precise and less invasive methods. They are in most telemanipulators, which use the surgeon's actions on one side to control the "effector" on the other side. Basically they are computer-assisted surgery. Robotically-assisted surgery was developed to overcome the limitations of pre-existing minimally-invasive surgical procedures and to enhance the capabilities of surgeons performing open surgery. The first robot to assist in surgery was the Arthrobot, which was developed and used for the first time in Vancouver in 1983. Intimately involved were biomedical engineer, Dr. James McEwen, Geof Auchinleck, a UBC engineering physics grad, and Dr. Brian Day as well as a team of engineering students. The robot was used in an orthopaedic surgical procedure on 12 March 1984, at the UBC Hospital in Vancouver. Over 60 arthroscopic surgical procedures were performed in the first 12 months, and a 1985 National Geographic video on industrial robots, The Robotics Revolution, featured the device. Other related robotic devices developed at the same time included a surgical scrub nurse robot, which handed operative instruments on voice command, and a medical laboratory robotic arm.

In 1985 a robot, the Unimation Puma 200, was used to place a needle for a brain biopsy using CT guidance.[45] In 1992, the PROBOT, developed at Imperial College London, was used to perform prostatic surgery by Dr. Senthil Nathan at Guy's and St Thomas' Hospital, London. This was the first pure robotic surgery in the world. Also the Robot Puma 560, a robot developed in 1985 by Kwoh et al. Puma 560 was used to perform neurosurgical biopsies with greater precision. Just like with any other technological innovation, this system led to the development of new and improved surgical robot called PROBOT. The PROBOT was specifically designed for transurethral resection of the prostate. Meanwhile, when PROBOT was being developed, ROBODOC, a robotic system designed to assist hip replacement surgeries was the first surgical robot that was approved by the FDA.[46] The ROBODOC from Integrated Surgical Systems (working closely with IBM) was introduced in 1992 to mill out precise fittings in the femur for hip replacement. The purpose of the ROBODOC was to replace the previous method of carving out a femur for an implant, the use of a mallet and broach/rasp.Further development of robotic systems was carried out by SRI International and Intuitive Surgical with the introduction of the da Vinci Surgical System and Computer Motion with the AESOP and the ZEUS robotic surgical system. The first robotic surgery took place atThe Ohio State University Medical Center in Columbus, Ohio under the direction of Robert E. Michler. Examples of using ZEUS include a fallopian tube reconnection in July 1998, a beating heart coronary artery bypass graft in October 1999,[51] and the Lindbergh Operation, which was a cholecystectomy performed remotely in September 2001.The original telesurgery robotic system that the da Vinci was based on was developed at SRI International in Menlo Park with grant support from DARPA and NASA.[53] Although the telesurgical robot was originally intended to facilitate remotely performed surgery in battlefield and other remote environments, it turned out to be more useful for minimally invasive on-site surgery. The patents for the early prototype were sold to Intuitive Surgical in Mountain View, California. The da Vinci senses the surgeon's hand movements and translates them electronically into scaled-down micro-movements to manipulate the tiny proprietary instruments. It also detects and filters out any tremors in the surgeon's hand movements, so that they are not duplicated robotically. The camera used in the system provides a true stereoscopic picture transmitted to a surgeon's console. Examples of using the da Vinci system include the first robotically assisted heart bypass (performed in Germany) in May 1998, and the first performed in the United States in September 1999;and the first all-robotic-assisted kidney transplant, performed in January 2009.[54] The da Vinci Si was released in April 2009, and initially sold for $1.75 million. In May 2006 the first artificial intelligence doctor-conducted unassisted robotic surgery on a 34-year-old male to correct heart arythmia. The results were rated as better than an above-average human surgeon. The machine had a database of 10,000 similar operations, and so, in the words of its designers, was "more than qualified to operate on any patient". In August 2007, Dr. Sijo Parekattil of the Robotics Institute and Center for Urology (Winter Haven Hospital and University of Florida) performed the first robotic assisted microsurgery procedure denervation of the spermatic cord for chronic testicular pain. In February 2008, Dr. Mohan S. Gundeti of theUniversity of Chicago Comer Children's Hospital performed the first robotic pediatric neurogenic bladder reconstruction. On 12 May 2008, the first image-guided MR-compatible robotic neurosurgical procedure was performed at University of Calgary by Dr. Garnette Sutherland using the NeuroArm. 
In June 2008, the German Aerospace Centre (DLR) presented a robotic system for minimally invasive surgery, the MiroSurge. In September 2010, the Eindhoven University of Technology announced the development of the Sofie surgical system, the first surgical robot to employ force feedback.[62] In September 2010, the first robotic operation at thefemoral vasculature was performed at the University Medical Centre Ljubljana by a team led by Borut Geršak.
Even various reports and inventions revealed that there are sound development was noticed in Surgical Robot although need much work in Neurosurgery. Several systems for stereotactic intervention are currently on the market for Neurogergery. The NeuroMate was the first neurosurgical robot, commercially available in 1997. Originally developed in Grenoble by Alim-Louis_Benabid's team, it is now owned by Renishaw. With installations in the United States, Europe and Japan, the system has been used in 8000 stereotactic brain surgeries by 2009. IMRIS Inc.'s SYMBIS(TM) Surgical System will be the version of NeuroArm, the world's first MRI-compatible surgical robot, developed for world-wide commercialization. Medtech's Rosa is being used by several institutions, including the Cleveland Clinic in the U.S, and in Canada at Sherbrooke University and the Montreal Neurological Institute and Hospital in Montreal (MNI/H). Between June 2011 and September 2012, over 150 neurosurgical procedures at the MNI/H have been completed robotized stereotaxy, including in the placement of depth electrodes in the treatment of epilepsy, selective resections, and stereotaxic biopsies.
All these instruments and techniques are not enough in the line of Neurosurgery. I think; we need sound software with proper mechanical devices for the surgery and working function of neurons. Applications should be designed for wide spectrum which has ability to understand the automatic nano mechanisms. It should be cost effective for all the levels of community of all continents.



Bibliography

1.     Estey, EP (2009). "Robotic prostatectomy: The new standard of care or a marketing success?". Canadian Urological Association Journal 3 (6): 488–90. PMC 2792423. PMID 20019980.
2.      Kolata, Gina (13 February 2010). "Results Unproven, Robotic Surgery Wins Converts". The New York Times. Retrieved11 March 2010.
3.      Robot-Assisted Surgery: Neurosurgery". Biomed.brown.edu. Retrieved 25 June 2013.
4.       ROBODOC history. Robodoc.com. Retrieved 29 November 2011.
5.      Carlson, Neil R."Physiology of Behavior".Pearson Education, Inc., 2013. p.134.
6.      addick, Ian (2006). "A simple dose gradient measurement tool to complement the conformity index". Journal of Neurosurgery 105: 194–201. doi:10.3171/sup.2006.105.7.194. PMID 18503356.

7.      Tsao, May N. (2012). "International Practice Survey on the Management of Brain Metastases: Third International Consensus Workshop on Palliative Radiotherapy and Symptom Control".Clinical Oncology 24 (6): e81–e92.

Salomonia cantoniensis Lour.

Salomonia cantoniensis Lour.
Fam: Polygalaceae
Distribution: E, C, S & SW China; Bhutan, Cambodia, India, Indonesia, Laos, Malaysia, Myanmar, Nepal, Thailand, Vietnam,
Philippines, Australia.
Ecology: Forests on hillslopes. Flowering: Jul.–Aug.; fruiting: Aug.–Oct.
Uses: Medicinal (folklore).
Herbs annual, erect, 5-25 cm tall. Roots slender, fragrant. Stem thin, multibranched, 3-winged, glabrous. Petiole 1.5-2 mm; leaf blade ovate-cordate or cordate, 5-16 × 5-12 mm, membranous, glabrous, 3-veined, base cordate or truncate, margin entire or slightly undulate, apex obtuse, mucronate. Spike terminal, 1-6 cm, elongated after anthesis. Flowers very small, 2-3 mm, sessile; bracts caducous, very small.

BIOMATERIALS

M. Kumari 

A biomaterial is any substance that has been engineered to interact with biological systems for medical purposes. It is either a therapeutic like in the repair / replace a tissue function of the body or a diagnostic one. It is nuvelle only about fifty year’s old science. The study of biomaterials is known as Biomaterial Science or Biomedical Engineering.  It encompasses elements of medicine, biology, chemistry, tissue engineering and materials science.   It can be derived from nature as well as synthesized using various chemical approaches using polymers, composite materials and metallic components.
The biomaterials are mostly used for different treatments which comprise whole or part of a living structure or bio-medical devices which replace a natural function or performs as well.   Such functions may be benign, like being used for a heart valve, or may be bioactive with a more interactive functionality such as Hydroxy-apatite coated hip implants. Biomaterials are also used every day in dental applications, surgery, and drug delivery. For example, a construct with impregnated pharmaceutical products can be placed into the body, which permits the prolonged release of a drug over an extended period of time. A biomaterial may also be an Autograft , Allograft or Xenograft used as a transplant material.

The key properties of the Biomaterials

The prime characters of biomaterials are that it does not illicit and adverse reaction when placed into service. The main key properties are following:
1.      Metallic biomaterials are used for load bearing applications and must have sufficient fatigue strength to endure the rigors of daily activity.
2.      Ceramic biomaterials are generally used for their hardness and wear resistance for application such as articulating surfaces in joints and in teeth as well as bone bonding surface in implants.
3.      Polymeric materials are usually used for their flexibility and stability, but have also been used for low friction articulating surface.
The most common applications of Biomaterials are following:

APPLICATION OF BIOMATERIALS

       I.            Joint replacements  
    II.            Bone plates  
 III.            Bone cement  
 IV.            Artificial ligaments and tendons  
    V.            Dental implants for tooth fixation  
 VI.            Blood vessel prostheses  
VII.            Heart valves etc.
The Biomaterials useful in above applications are must be compatible with the body with clinical settings. All manufacturing companies are also required to ensure traceability of all of their products so that if a defective product is discovered, others in the same batch may be traced.

HISTORICAL DEVELOPMENT

Some of the earliest biomaterial applications were as far back as ancient Phoenicia where loose teeth were bound together with gold wires for tying artificial ones to neighboring teeth. In the early 1900’s bone plates were successfully implemented to stabilize bone fractures and to accelerate their healing. While by the time of the 1950’s to 60’s, blood vessel replacement were in clinical trials and artificial heart valves and hip joints were in development.

DESIGN FACTORS

Even in the preliminary stages of this field, surgeons and engineers identified materials and design problems that resulted in premature loss of implant function through mechanical failure, corrosion or inadequate biocompatibility of the component. Key factors in a biomaterial usage are its biocompatibility, bio-functionality, and availability to a lesser extent. Ceramics are ideal candidates with respect to all the above functions, except for their brittle behavior.
When a synthetic material is placed within the human body, tissue reacts towards the implant in a variety of ways depending on the material type. The mechanism of tissue interaction (if any) depends on the tissue response to the implant surface. In general, there are three terms in which a biomaterial may be described in or classified into representing the tissues responses. These are bio-inert, bio-resorbable, and bioactive, which are well covered in range of excellent review papers.CLASSIFICATIONS

BIOINERT BIOMATERIALS

The term bio-inert refers to any material that once placed in the human body has minimal interaction with its surrounding tissue, examples of these are stainless steel, titanium, alumina, partially stabilized zirconia, and ultra high molecular weight polyethylene. Generally a fibrous capsule might form around bio-inert implants hence its bio-functionality relies on tissue integration through the implant.

BIOACTIVE BIOMATERIALS

Bioactive refers to a material, which upon being placed within the human body interacts with the surrounding bone and in some cases, even soft tissue. This occurs through a time – dependent kinetic modification of the surface, triggered by their implantation within the living bone. An ion – exchange reaction between the bioactive implant and surrounding body fluids – results in the formation of a biologically active carbonate apatite (CHAp) layer on the implant that is chemically and crystallo-graphically equivalent to the mineral phase in bone. Prime examples of these materials are synthetic hydroxyapatite [Ca10(PO4)6(OH)2], glass ceramic A-W and bio-glass.

BIORESORBABLE BIOMATERIALS

Bio-resorbable refers to a material that upon placement within the human body starts to dissolve and slowly replaced by advancing tissue (such as bone). Common examples of bio-resorbable materials are tricalcium phosphate [Ca3(PO4)2] and Poly (lactic-co-glycolic acid) copolymers. Calcium oxide, calcium carbonate and gypsum are other common materials that have been utilized during the last three decades.
POLY (LACTIC-CO-GLYCOLIC ACID): IMPORTANT BIOMATERIALS
It is a copolymer which is used in a host of Food and Drug Administration (FDA) approved therapeutic devices, owing to its biodegradability and biocompatibility. Poly (lactic-co-glycolic-acid) (PLGA) is synthesized by means of ring-opening co-polymerization of two different monomers, the cyclic dimers (1,4-dioxane-2,5-diones) of glycolic acid and lactic acid. Polymers can be synthesized as either random or block copolymers thereby imparting additional polymer properties. Common catalysts used in the preparation of this polymer include tin(II) 2-ethylhexanoate, tin(II) alkoxides, or aluminum isopropoxide. During polymerization, successive mono-meric units (of glycolic or lactic acid) are linked together in PLGA by ester linkages, thus yielding a linear, aliphaticpolyester as a product.
Depending on the ratio of lactide to glycolide used for the polymerization, different forms of PLGA can be obtained: these are usually identified in regard to the molar ratio of the monomers used (e.g. PLGA 75:25 identifies a copolymer whose composition is 75% lactic acid and 25% glycolic acid). The crystallinity of PLGAs will vary from fully amorphous to fully crystalline depending on block structure and molar ratio. PLGAs typically show a glass transition temperature in the range of 40-60 °C. PLGA can be dissolved by a wide range of solvents, depending on composition. Higher lactide polymers can be dissolved using chlorinated solvents whereas higher glycolide materials will require the use of fluorinated solvents such as HFIP.
PLGA degrades by hydrolysis of its ester linkages in the presence of water. It has been shown that the time required for degradation of PLGA is related to the monomers' ratio used in production: the higher the content of glycolide units, the lower the time required for degradation as compared to predominantly lactide materials. An exception to this rule is the copolymer with 50:50 monomers' ratio which exhibits the faster degradation (about two months). In addition, polymers that are end-capped with esters (as opposed to the freecarboxylic acid) demonstrate longer degradation half-lives.
PLGA has been successful as a biodegradable polymer because it undergoes hydrolysis in the body to produce the original monomers, lactic acid and glycolic acid. These two monomers under normal physiological conditions are by-products of various metabolic pathways in the body. Since the body effectively deals with the two monomers, there is minimal systemic toxicity associated with using PLGA for drug delivery or biomaterial applications. Also, the possibility to tailor the polymer degradation time by altering the ratio of the monomers used during synthesis has made PLGA a common choice in the production of a variety of biomedical devices, such as, grafts, sutures, implants, prosthetic devices, surgical sealant films, micro and nanoparticles.  Specific examples of use include:
a.       Successful in the delivery of amoxicillin for the treatment listeriosis (treatment of Listeria monocytogenes infection).
b.      A commercially available drug delivery device using PLGA is Lupron Depot for the treatment of advanced prostate cancer.
c.       Prophylactic delivery of the antibiotic vancomycin into the central nervous system when applied to the surface of the brain after brain surgery

Bibliography

  1. http://pubs.rsc.org/en/content/articlelanding/2001/dt/b007852m#!divAbstract.
  2. http://www.azom.com/article.aspx?ArticleID=2630
  3. https://en.wikipedia.org/wiki/PLGA
  4. Farazuddin, Mohammad; Chauhan, Arun; Khan, Raza M.M.; Owais, Mohammad.  (2010-08-05). "Amoxicillin bearing microparticles: potential in treatment of Listeria monocytogenes infection in Swiss albino mice". Bioscience Reports (* Interdisciplinary Biotechnology Unit, Aligarh Muslim University, Aligarh-202002, India; and,  Department of Chemistry, Aligarh Muslim University, Aligarh-202002, India.: Biochemical Society) 31 (4): 265–72. doi:10.1042/BSR20100027
  5. Dissolvable Plastic Nanofibers could Treat Brain Infections".Scientific Computing (Advantage Business Media). August 28, 2013. Retrieved September 3, 2013.
  6. Pavot, V; Berthet, M; Rességuier, J; Legaz, S; Handké, N; Gilbert, SC; Paul, S; Verrier, B (December 2014). "Poly(lactic acid) and poly(lactic-co-glycolic acid) particles as versatile carrier platforms for vaccine delivery.". Nanomedicine (London, England) 9 (17): 2703–18. doi:10.2217/nnm.14.156.